Liftmaster LM21AFCB Advance Fire Control Release Device Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Bezpieczeństwo Liftmaster LM21AFCB Advance Fire Control Release Device. LiftMaster LM21AFCB Advance Fire Control Release Device User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
OO WW NN EE RR SS MM AA NN UU AA LL
MM OO DD EE LL SS
LL MM 22 11 AA FF CC BB
LL MM 22 11 AA FF CC BB VV BB
AADDVVAANNCCEE FFIIRREE CCOONNTTRROOLL RREELLEEAASSEE DDEEVVIICCEE
The Chamberlain Group, Inc.
845 Larch Avenue
Elmhurst, Illinois 60126-1196
www.liftmaster.com
FM
APPAPPROVOVED D
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - MM OO DD EE LL SS

OO WW NN EE RR ’’ SS MM AA NN UU AA LLMM OO DD EE LL SSLL MM 22 11 AA FF CC BBLL MM 22 11 AA FF CC BB VV BBAADDVVAANNCCEE FFIIRREE C

Strona 2 - INTRODUCTION

10TESTINGTESTING Testing does not affect normal operation of alarm system whenconnected to release device/control panel. Testing of the releasedevice

Strona 3

11TESTINGTEST RELEASE DEVICE AND DOOR OPERATORAUTOMATIC DOOR CLOSURE TESTS (CONTINUED)(MOTORIZED DOORS ONLY) Three-Cycle Obstruction Test1. With the d

Strona 4 - INSTALLATION

12TEST RELEASE DEVICE WITH BATTERY BACKUPWITHOUT AC POWERMECHANICAL DOOR CLOSURE TEST This test verifies a mechanical release in absence of power to t

Strona 5 - WIRE ROUTING

BatteryPresentGreen(Fig. 13)If lit, batteries have been installed correctly and arecharging or have been fully charged.If the LED does not come back o

Strona 6 - POWER CONNECTION

MAINTENANCETo avoid SERIOUS PERSONAL INJURY or DEATH fromelectrocution, disconnect ALL electric and battery powerBEFORE performing ANY maintenance.ATT

Strona 7 - ACCESSORIES

15ACCESSORIES AND REPLACEMENT PARTSACCESSORIESITEM PART # DESCRIPTION1 LM8100 Smoke Detector - 120V Photo2 LM8100T Smoke Detector - 120V Photo with Th

Strona 8 - OPTIONAL CONNECTIONS

MODEL NO. DESCRIPTIONLM2W-B 24Vdc 2-Wire Photo 2W-BLM2WT-B 24Vdc 2-Wire Photo with Thermal 2WT-BLM4W-B 24Vdc 4-Wire Photo 4W-BLM4WT-B 24Vdc 4-Wire Pho

Strona 9 - ADJUSTMENTS

When you see these Safety Symbols and Signal Words on thefollowing pages, they will alert you to the possibility of seriousinjury or death if you do n

Strona 10 - TESTING

INTRODUCTION3AGENCY REQUIREMENTSInstallation and testing to factory specifications shall beperformed by factory authorized personnel for proper operat

Strona 11

4INSTALLATIONClassification:Releasing device as defined by Underwriters Laboratories.Installation Requirements:Intended for “Indoor Dry” locations; al

Strona 12 - WITHOUT AC POWER

5WIRING POWER WIRING CONNECTIONSThis device is designed to be used on motorized doorsincorporating a reversing feature safety edge. Verify wiringconfi

Strona 13 - TROUBLESHOOTING

CONNECTIONS FROM DEVICE TO THE OPERATORNOTE: For low voltage wiring #18 AWG is recommended.OPERATOR CONNECTIONS1. Connect terminals 11 and 12 from the

Strona 14 - MAINTENANCE

7CONNECTIONS OF INITIATING DEVICES ANDACCESSORIESA maximum of 4 smoke detectors may be installed with thisdevice. Refer to NFPA 72 and NFPA 80 for ins

Strona 15 - HOW TO ORDER REPAIR PARTS

8WIRINGTo prevent DAMAGE to the circuit board, auxiliary limit switchesMUST be provided as dry contacts and may not be used inconjunction with the sim

Strona 16 - APPENDIX

1 Motorized door. The device will attempt to close the door withthe motor before releasing.Manual door. The device will drop the door without attempti