LA500 &
LA500-S
VEHICULAR SWING GATE OPERATOR
INSTALLATION MANUAL
UL325
compliant
UL991
compliant
This model is for use on vehicular
passage gates ONLY and not
intended for use on pedestrian
passage gates.
This model is intended for use in
Class I, II, III and IV vehicular swing
gate applications.
THIS PRODUCT IS TO BE
INSTALLED AND SERVICED BY
A TRAINED GATE SYSTEMS
TECHNICIAN ONLY.
Visit www.liftmaster.com to
locate a professional installing
dealer in your area.
Your model may look different than the model illustrated in this manual.
Przeglądanie stron 0
1 2 3 4 5 6 ... 51 52

Podsumowanie treści

Strona 1 - LA500 &

LA500 & LA500-SVEHICULAR SWING GATE OPERATORINSTALLATION MANUALUL325compliantUL991compliantThis model is for use on vehicular passage gates ONLY a

Strona 2

8OPERATOR SPECIFICATIONSThis model is intended for use in vehicular swing gate applications:OPERATOR SPECIFICATIONS + CARTON INVENTORY & OPERATOR

Strona 3 - TABLE OF CONTENTS

9FEATURES INTRODUCTIONFEATURESOPERATOR FEATURES• Advanced “Centerpiece” Control Board• 120 Vac Power Input (standard) - Optional Input Selection:

Strona 4 - UL325 MODEL CLASSIFICATIONS

10PREPARATIONVEHICLE LOOPSThe vehicle loops allow the gate to stay open when vehicles are obstructing the gate path. Suggested for vehicles 14 feet (4

Strona 5

11SITE PREPARATIONINSTALLATION TYPESPULL-TO-OPENPUSH-TO-OPENTop ViewHeavy Steel Plate for Reinforcement (Not provided)Back Steel Bracket (Reinforce if

Strona 6 - GATE CONSTRUCTION INFORMATION

12MOUNTING OPTIONSPREPARATION!!!!!DO NOT weld the crossbar on just a few pickets, or they could bend.An off-level installation may cause the gate or o

Strona 7 - NON-CONTACT SENSORS

13MANUAL RELEASE + DETERMINE THE POSITION OF THE POST BRACKETINSTALLATIONMANUAL RELEASE1 Insert the key into the lock and turn it 180 degrees counte

Strona 8 - IMPORTANT SAFETY INFORMATION

14DETERMINE THE POSITION OF THE GATE BRACKET + WELD THE BRACKETSINSTALLATIONDETERMINE THE POSITION OF THE GATE BRACKETWELD THE BRACKETS1 Position th

Strona 9 - MAINTENANCE AND OPERATION

15ATTACH THE OPERATOR TO THE BRACKETSINSTALLATION ATTACH THE OPERATOR TO THE BRACKETS1 Attach the operator to the post bracket with the bolt, mount

Strona 10 - INTRODUCTION

16STANDARD CONTROL BOXINSTALLATIONABCFor Large Metal Control Box installation, refer to the following page.STANDARD CONTROL BOXMOUNT THE CONTROL BOXTh

Strona 11

17NOTE: The post mount option is not recommended for the 33AH battery application.2 The control box can be mounted to a post with 'U' bolt

Strona 13 - INSTALLATION TYPES

18OFF560180M NMAXF REDEPTOPENEXITSHADOWCLOSEEYES/NTERRUPTLOCKN OCOMN C+ -+ -ACCESSORYPOWERON SWEXPBOARDLA S 2 U P Y4 V L S-

Strona 14

191 Insert the operator cable through the watertight connector (provided) as shown.2 Extend the operator cable and wires to the Gate 1 connector a

Strona 15 - INSTALLATION

20DUAL GATES ONLYDUAL GATES ONLYWIRINGBefore digging, contact local underground utility locating companies. The following items are required to comple

Strona 16

21DUAL GATES ONLYWIRINGDUAL GATES ONLY CONTINUED...S T OPENSET CLOSEMOVEGA EOF506080NOFFOESOPI PUT POW RA T CHA GI GT MERG TE MOV NGATT OWCC PWR OV D

Strona 17

22POWER WIRING INTRODUCTION + POWER WIRING (STANDARD CONTROL BOX)WIRING POWER WIRING INTRODUCTIONThe standard control box can be wired for either 120

Strona 18

23Junction Box CoverLARGE METAL CONTROL BOX (XLM)POWER WIRING (LARGE METAL CONTROL BOX [XLM])WIRINGCONNECT BATTERIES1 Unplug the battery connector t

Strona 19

24 POWER WIRING (SOLAR PANELS)POWER WIRING (SOLAR PANELS)WIRINGSOLAR PANELS ARE NOT PROVIDED. SEE ACCESSORIES.Solar Application requirements:• Large

Strona 20 - EARTH GROUND ROD

25POWER WIRING (SOLAR PANELS) CONTINUED...SET OP NSET CLO EMOVEGATE5106S C N S)O ENCLO ETOP AT CH RG NGTE M VNG CC WR O LOD SST TUS“ REDOESHC OSN E

Strona 21

26ENGAGE THE OPERATORWIRINGENGAGE THE OPERATOR1 Turn the release lever clockwise 180°. This engages the motor.2 Turn the key clockwise 180°. This

Strona 22 - DUAL GATES ONLY

27OPEN limitCLOSE limit!SET OPENSET CLOSEMOVEGATE5106S O )OPENCLOSESTOPNPUT POWERBA T CHARG NGIMERATE MOVNGB TT LOWACC PWR OVLDI GNOST CCODESSTATUSIRE

Strona 23 - DUAL GATES ONLY CONTINUED

1When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you d

Strona 24 - POWER WIRING INTRODUCTION

28!OPEN limitCLOSE limit!SET O ENSET C OSEMOVEGATEO50080INS C ND )OP NCL SSTOPN UT OW RA T C AR I GMERA E MO NGA T OWCC WR O LT CST TUSHL SEE E /OC

Strona 25 - CONNECT BATTERIES

29SET O ENS T LO EM VEG TEOF50080NMAXOFFNPENLO ESTOPPU PO ERA T HA GNGA E MO I G C PWR V DAG OS COD ST T U SB“ REDE TO EHC O EY SN ER U TOC

Strona 26 - POWER WIRING (SOLAR PANELS)

30!!!!!!ADEFBCMANUAL RELEASE + RESET BUTTON + PARTY MODE + OPERATOR ALARM + REMOTE CONTROLOPERATIONMANUAL RELEASEIn case of a power failure, the opera

Strona 27

31LIFTMASTER INTERNET GATEWAYTo program the operator to the LiftMaster Internet Gateway:USING THE LEARN BUTTON ON THE OPERATOR’S CONTROL BOARD1 Conn

Strona 28 - ENGAGE THE OPERATOR

32SET OPENSET CLOSEMOVEGATEOFF51060180MINMAX(SECONDS)OFFONOPENCLOSESTOPINPUT POWERBATT CHARGINGTIMERGATE MOVINGBATT LOWACC PWR OVLDDIAGNOSTICCODESS TA

Strona 29 - ADJUSTMENT

33ADDITIONAL FEATURESA Single Button Control, SBC (2 terminals)Gate command sequence - Open, Stop, Close, Stop, ...Soft open (maintained switch does n

Strona 30

34EXPANSION BOARD OVERVIEWADDITIONAL FEATURESTo AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to t

Strona 31 - PROGRAMMING

35ComSingle Button Control StationASBC3-Button Control StationBCComOpenCloseStopAUX Relay 2 N.C.ComAUX Relay 2 N.O.AUX Relay 1 N.C.ComAUX Relay 1 N.O.

Strona 32 - OPERATION

36SET OPENSET CLOSEMOVEGATE51060SECO DS)OFFONOPENNPUT POWERBATT CHARGINGT MERGATE M STATUSN ACCESSORYPOWERON SWEXPBOARDXMIT ER

Strona 33 - ADDITIONAL FEATURES

37GATE OPERATOR SETUP EXAMPLESADDITIONAL FEATURESGATE OPERATOR SETUP EXAMPLESThe following are example setups for the gate operator. Your specific sit

Strona 34

2In order to complete a proper installation you must satisfy the entrapment protection chart shown. That means that the installation must have one pri

Strona 35

38INITIAL LIMITS AND FORCE ADJUSTMENTFor dual gate applications the limits will have to be set for each operator. The gate MUST be attached to the ope

Strona 36

39NOTES:• Severe or high cycle usage will require more frequent maintenance checks.• It is suggested that while at the site voltage readings be tak

Strona 37

40The control board is equipped with many LEDs that have a variety of functions. The control board LEDs indicate the status of the operator, assist wi

Strona 38

41INPUT LEDSOPEN INPUT OFF Input inactiveON Input activeBLINK Input active on other operatorCLOSE INPUT OFF Input inactiveON Input activeBLINK Input a

Strona 39

42TROUBLESHOOTING CHARTTROUBLESHOOTINGFAULT POSSIBLE CAUSES CORRECTIONSOperator does not run and diagnostic LED not on.a) No power to control boardb)

Strona 40

43TROUBLESHOOTING CHARTTROUBLESHOOTINGFAULT POSSIBLE CAUSES CORRECTIONSGate opens, but will not close.a) Check DIAGNOSTIC LEDsb) Open control activec)

Strona 41 - MAINTENANCE

44TROUBLESHOOTING CHARTTROUBLESHOOTINGFAULT POSSIBLE CAUSES CORRECTIONSAlarm sounds for 5 minutes or alarm sounds with a command.a) Double entrapment

Strona 42 - TROUBLESHOOTING

45STANDARD CONTROL BOXITEM PART NUMBER DESCRIPTION1 K74-34582-1 Standard Plastic Control Box Only2 K76-36296-1 Outlet3 K75-36635 Control Board B

Strona 43

46To protect against fire and electrocution:• DISCONNECT power and battery BEFORE installing or servicing operator.For continued protection against

Strona 44

47SET OPENSET CLOSEMOVEGATEOFF51060180M NMAX(SECONDSOFFONOPENCLOSESTOPNPUT POWERBATT CHARG NGT MERGATE MOV NGBATT LOWACC PWR OVLDD AGNOST CCODESSTATUS

Strona 45

3 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one com

Strona 46

48PHOTOELECTRIC SENSORS (NON-CONTACT)The photoelectric sensors are designed to detect an obstacle in the path of the electronic beam and stop the oper

Strona 47 - REPAIR PARTS

49WARRANTYLIFTMASTER 2 YEAR LIMITED WARRANTYThe Chamberlain Group, Inc. (“Seller”) warrants to the first purchaser of this product, for the structure

Strona 48 - Wire Loop

01-36213G © 2013, The Chamberlain Group, Inc. – All Rights Reserved845 Larch AvenueElmhurst, Illinois 60126-1196

Strona 49 - WIRING DIAGRAMS

41. GENERAL REQUIREMENTS1.1 Gates shall be constructed in accordance with the provisions given for the appropriate gate type listed, refer to ASTM

Strona 50 - ACCESSORIES

5To prevent SERIOUS INJURY or DEATH from a moving gate:• Entrapment protection devices MUST be installed to protect anyone who may come near a movin

Strona 51 - WARRANTY

6INSTALLATIONTo prevent SERIOUS INJURY or DEATH from a moving gate:• Pinch points must be guarded at all times. Install enclosed-style gate tracks a

Strona 52 - Elmhurst, Illinois 60126-1196

7To prevent SERIOUS INJURY or DEATH from a moving gate:• Entrapment protection devices MUST be installed to protect anyone who may come near a movin