Liftmaster CSW24V High-Cycle Commercial DC Swing Gate Operato Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Bezpieczeństwo Liftmaster CSW24V High-Cycle Commercial DC Swing Gate Operato. LiftMaster CSW24V High-Cycle Commercial DC Swing Gate Operator User Manual [de] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
CSW24V™ & CSW24VH™
VEHICULAR SWING GATE OPERATOR
INSTALLATION MANUAL
Your model may look different than the model illustrated in this manual.
UL991
compliant
UL325
compliant
THIS PRODUCT IS TO BE
INSTALLED AND SERVICED BY A
TRAINED GATE SYSTEMS
TECHNICIAN ONLY.
Visit www.liftmaster.com to
locate a professional installing
dealer in your area.
This model is for use on vehicular
passage gates ONLY and not
intended for use on pedestrian
passage gates.
This model is intended for use in
Class I, II, III and IV vehicular
swing gate applications.
Przeglądanie stron 0
1 2 3 4 5 6 ... 51 52

Podsumowanie treści

Strona 1 - CSW24V™ & CSW24VH™

CSW24V™ & CSW24VH™VEHICULAR SWING GATE OPERATORINSTALLATION MANUALYour model may look different than the model illustrated in this manual.UL991com

Strona 2

8INTRODUCTIONOPERATOR SPECIFICATIONS + CARTON INVENTORY & OPERATOR DIMENSIONSOPERATOR SPECIFICATIONSThis model is intended for use in vehicular sw

Strona 3 - TABLE OF CONTENTS

9INTRODUCTIONFEATURESFEATURESOPERATOR FEATURES• Advanced “Centerpiece” Control Board• AC Surge Protection and EMI Filter Board - Main AC voltage i

Strona 4 - UL325 MODEL CLASSIFICATIONS

10PREPARATIONSITE PREPARATIONCheck the national and local building codes BEFORE installation.GATE CONDUIT & CONCRETE PADGate must be constructed a

Strona 5

11SITE PREPARATIONSAFETYEntrapment protection devices are required to protect against any entrapment or safety conditions encountered in your gate app

Strona 6 - GATE CONSTRUCTION INFORMATION

12INSTALLATIONSTANDARD INSTALLATION ONLYSTANDARD INSTALLATION ONLYFor compact installation start on page 16.DETERMINE LOCATION FOR CONCRETE PAD AND OP

Strona 7 - NON-CONTACT SENSORS

13CHART INSTALLATIONRefer to the illustration to determine the measurements and location of the concrete pad.INSTALLATIONSTANDARD INSTALLATION ONLY123

Strona 8 - IMPORTANT SAFETY INFORMATION

14STANDARD INSTALLATION ONLY CONTINUED...CONCRETE PAD AND OPERATOR ATTACHMENTCheck the national and local building codes before installation. NOTE: Wh

Strona 9 - MAINTENANCE AND OPERATION

15INSTALLATIONSTANDARD INSTALLATION ONLYSTANDARD INSTALLATION ONLY CONTINUED...POSITION THE GATE BRACKETNOTE: It may be necessary to attach horizontal

Strona 10 - INTRODUCTION

16INSTALLATIONCOMPACT INSTALLATION ONLY COMPACT INSTALLATION ONLYDETERMINE LOCATION FOR CONCRETE PAD AND OPERATORDO NOT run the operator until instruc

Strona 11

17INSTALLATIONCOMPACT INSTALLATION ONLYCOMPACT INSTALLATION ONLY CONTINUED...SHORTEN THE OPERATOR ARMFor a compact installation the operator arm will

Strona 13 - EARTH GROUND ROD

18INSTALLATIONINSTALLATION CONTINUED... INSTALLATION CONTINUED...WELD THE OPERATOR ARMOnce the operator arm measurements are verified:1 Weld the gate

Strona 14 - INSTALLATION

191 Connect the entrapment protection device to the EYES EDGE terminal on the control board: • Close Photoelectric Sensor Entrapment Protection:

Strona 15

20POWER WIRINGWIRINGPOWER WIRINGThis operator can be wired for either 120 Vac or 240 Vac or a solar panel (not provided). Follow the directions accord

Strona 16

21POWER WIRINGWIRINGSOLAR PANEL(S)NOT PROVIDED. SEE ACCESSORIES.Solar Application requirements:• A minimum of four 10W solar panels (Model SOLPNL10W

Strona 17

22J15 PlugJumper Black Wire Red Wire The batteries are charged in the circuit by the integrated transformer. The batteries are for battery backup.1

Strona 18

23CONNECT BATTERIESWIRINGThe batteries are charged in the circuit by the integrated transformer. The batteries are for battery backup or solar install

Strona 19

24DUAL GATES ONLYWIRINGDUAL GATES ONLY WIRELESS DUAL GATESTO ACTIVATE THE WIRELESS FEATURE:1 Choose an operator to be the network primary operator.

Strona 20

25DUAL GATES ONLY CONTINUED...2134Before digging, contact local underground utility locating companies. Use PVC conduit to prevent damage to cables. D

Strona 21

26OPEN limitCLOSE limit!31245To reduce the risk of SEVERE INJURY or DEATH: • Without a properly installed safety reversal system, persons (particula

Strona 22 - POWER WIRING

27FINE TUNE THE FORCEThe FORCE DIAL on the control board is used for fine tuning the force in cases where wind or environmental changes may affect the

Strona 23 - POWER WIRING CONTINUED

1SAFETYWhen you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if

Strona 24 - CONNECT BATTERIES

28ERASE ALL CODES1 Press and release the LEARN RADIO button (operator will beep and green XMITTER LED will light).2 Press and hold the LEARN RADIO

Strona 25 - 33AH BATTERIES

29INSTALL THE COVERFINISH INSTALLATIONTO INSTALL THE COVER1 Remove the operator arm from the output shaft by releasing the handle.2 Align the tabs

Strona 26 - DUAL GATES ONLY

30MANUAL DISCONNECTPress the reset switch to RESET/DISCONNECT. Release the handle on the operator arm to allow the gate to be opened and closed manual

Strona 27 - DUAL GATES ONLY CONTINUED

31GATE OPERATOR SETUP EXAMPLESADDITIONAL FEATURESGATE OPERATOR SETUP EXAMPLESThe following are example setups for the gate operator. Your specific sit

Strona 28 - ADJUSTMENT

32CONTROL BOARD OVERVIEWADDITIONAL FEATURESCONTROL BOARD OVERVIEW1 234 56 7891 SET OPEN Button: The SET OPEN button sets the OPEN limit. See Adjust L

Strona 29 - OPEN limit

33ADDITIONAL FEATURESAOpen Input (& common)(3-Button Control Station, 4 terminals total)Open command - opens a closed gate.Hard open (maintained s

Strona 30 - ERASE ALL CODES

34EXPANSION BOARD OVERVIEWADDITIONAL FEATURESTo AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to t

Strona 31 - FINISH INSTALLATION

35ComSingle Button Control StationASBC3-Button Control StationBCComOpenCloseStopAUX Relay 2 N.C.ComAUX Relay 2 N.O.AUX Relay 1 N.C.ComAUX Relay 1 N.O.

Strona 32 - OPERATION

36FEATURE PRIMARY OPERATOR SECONDARY OPERATORQUICK CLOSE Switch ON OFFANTI-TAIL Switch ON OFFLOW BATT Switch Battery Fail OPEN: OPENBattery Fail CLOSE

Strona 33 - ADDITIONAL FEATURES

37LIMIT SETUP WITH A REMOTE CONTROLADDITIONAL FEATURESLIMIT SETUP WITH A REMOTE CONTROL To set the limits using a remote control, first you will need

Strona 34

2SAFETYUL325 MODEL CLASSIFICATIONSUL325 MODEL CLASSIFICATIONSCLASS I – RESIDENTIAL VEHICULAR GATE OPERATORA vehicular gate operator (or system) intend

Strona 35

38LIFTMASTER INTERNET GATEWAYADDITIONAL FEATURESLIFTMASTER INTERNET GATEWAYTo program the operator to the LiftMaster Internet Gateway:USING THE LEARN

Strona 36

39NON SOLARWIRING DIAGRAMSTo protect against fire and electrocution:• DISCONNECT power and battery BEFORE installing or servicing operator.For contin

Strona 37

40CONTROL BOARD LEDSThe control board is equipped with many LEDs that have a variety of functions. The control board LEDs indicate the status of the o

Strona 38

41INPUT LEDSOPEN INPUT OFF Input inactiveON Input activeBLINK Input active on other operatorCLOSE INPUT OFF Input inactiveON Input activeBLINK Input a

Strona 39

42TROUBLESHOOTING CHARTTROUBLESHOOTINGFAULT POSSIBLE CAUSES CORRECTIONSOperator does not run and diagnostic LED not on.a) No power to control boardb)

Strona 40

43TROUBLESHOOTING CHARTTROUBLESHOOTINGFAULT POSSIBLE CAUSES CORRECTIONSGate opens, but will not close.a) Check DIAGNOSTIC LEDsb) Open control activec)

Strona 41 - NG DIAGRAM

44TROUBLESHOOTING CHARTTROUBLESHOOTINGFAULT POSSIBLE CAUSES CORRECTIONSAlarm beeps three times with a command.a) Low battery with loss of AC/solar pow

Strona 42 - TROUBLESHOOTING

45PHOTOELECTRIC SENSORS (NON-CONTACT)The photoelectric sensors are designed to detect an obstacle in the path of the electronic beam and stop the oper

Strona 43

46REPAIR PARTSNOT SHOWN K94-36540 Wiring Harness with ID resistor assembly K94-36250 Battery Harness (for 7AH batteries) Q103 Swivel Arm Assembl

Strona 44

47REPAIR PARTS12345678910 11121314151617181920212223242526272829

Strona 45

3SAFETYSAFETY INSTALLATION INFORMATIONSAFETY INSTALLATION INFORMATION1. Vehicular gate systems provide convenience and security. Gate systems are co

Strona 46

48NOTES:• Severe or high cycle usage will require more frequent maintenance checks.• It is suggested that while at the site voltage readings be tak

Strona 47 - ACCESSORIES

49WARRANTY7 YEAR RESIDENTIAL / 5 YEAR COMMERCIAL CSW24V™ AND CSW24VH™ LIMITED WARRANTYThe Chamberlain Group, Inc. (“Seller”) warrants to the first pur

Strona 48 - REPAIR PARTS

01-35592G © 2012, The Chamberlain Group, Inc. – All Rights Reserved845 Larch AvenueElmhurst, Illinois 60126-1196

Strona 49

4SAFETYGATE CONSTRUCTION INFORMATIONGATE CONSTRUCTION INFORMATIONVehicular gates should be installed in accordance with ASTM F2200: Standard Specifica

Strona 50 - MAINTENANCE

5To prevent SERIOUS INJURY or DEATH from a moving gate:• Entrapment protection devices MUST be installed to protect anyone who may come near a movin

Strona 51 - WARRANTY

6SAFETYIMPORTANT SAFETY INFORMATIONIMPORTANT SAFETY INFORMATIONINSTALLATIONTo prevent SERIOUS INJURY or DEATH from a moving gate:• Pinch points must

Strona 52 - Elmhurst, Illinois 60126-1196

7SAFETYIMPORTANT SAFETY INFORMATIONIMPORTANT SAFETY INFORMATION CONTINUED...ADDITIONAL FEATURESTo prevent SERIOUS INJURY or DEATH from a moving gate:•

Komentarze do niniejszej Instrukcji

Brak uwag